The analog input modules convert analog signals from the process into digital signals for processing within the PLC. The modules feature: Resolution from 9 to 15 bits + sign (for different conversion times), configurable Different measuring ranges; the basic current/voltage range settings are adjusted mechanically via measurement range modules. Fine adjustments are made with the STEP 7 Hardware Configuration tool on a PG.
Nội dung trích xuất từ tài liệu:
Analog Modules - Analog input SM 331CA 01 Analog Modules - Analog input SM 331Analog Modules - Analog input SM 331Overview Analog inputs For connection of voltage and current sensors, thermocouples, resistors and resistance thermometersApplicationAnalog input modules can be used to connect the PLC to analog process signals. They are suitable for the connection of voltage and current sensors,thermocouples, resistors and resistance thermometers.FunctionThe analog input modules convert analog signals from the process into digital signals for processing within the PLC.The modules feature: Resolution from 9 to 15 bits + sign (for different conversion times), configurable Different measuring ranges; the basic current/voltage range settings are adjusted mechanically via measurement range modules. Fine adjustments are made with the STEP 7 Hardware Configuration tool on a PG. Interrupt capability; the modules transmit diagnostic and limit value interrupts to the programmable controller’s CPU Diagnostics; the module sends detailed diagnostic information to the CPU.Technical specifications 6ES7 331-7KF02-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-1KF01-0AB0 6ES7 331-7KB02-0AB0Voltages and currentsLoad voltage L+ Rated value (DC) 24 V 24 V 24 V Reverse polarity protection Yes Yes YesCurrent consumptionSeite 1 von 5CA 01 Analog Modules - Analog input SM 331 from load voltage L+ (no load), 200 mA 50 mA 80 mA max. from backplane bus 5 V DC, 50 mA 60 mA 90 mA 50 mA max. Power dissipation, typical 1W 1.5 W 0.4 W 1.3 WConnection system Requisite front connector 20-pin 20-pin 40-pin 20-pinClock synchronism Clock synchronous operation No Yes No NoAnalog inputs Number of analog inputs 8 8 8 2 Number of analog inputs for 4 8 1 resistance measurement Length of cable shielded, max 200 m; 50 m at 80 mV and 200 m 200 m; max. 50 m at 50 mV 200 m; 50 m at 80 mV and thermocouples thermocouples Permiss. input voltage for voltage 20 V; permanent; 75V for max. 1s 20 V; 20 V permanent, 75 V for max. 30 V; 12 V continuous, 30 V for max. 20 V; permanent; 75V for max. 1s input (destr. limit), max. (pulse duty ratio 1:20) 1 s (pulse duty ratio 1:20) 1s (pulse duty ratio 1:20) Perm. input volt. for the current 40 mA 40 mA 40 mA 40 mA input (destr. lim.), max.Input ranges (rated values), voltages 0 to +10 V Yes 1 to +5 V Yes Yes Yes Yes 1 to +10 V Yes No -1 V to +1 V Yes Yes Yes Yes -10 V to +10 V Yes Yes Yes Yes -2.5 V to +2.5 V Yes No Yes -250 mV to +250 mV Yes No Yes -5 V to +5 V Yes Yes Yes Yes -50 mV to +50 mV Yes -500 mV to +500 mV Yes Yes Yes -80 mV to +80 mV Yes YesInput ranges (rated values), currents 0 to 20 mA Yes Yes ...
Nội dung trích xuất từ tài liệu:
Analog Modules - Analog input SM 331CA 01 Analog Modules - Analog input SM 331Analog Modules - Analog input SM 331Overview Analog inputs For connection of voltage and current sensors, thermocouples, resistors and resistance thermometersApplicationAnalog input modules can be used to connect the PLC to analog process signals. They are suitable for the connection of voltage and current sensors,thermocouples, resistors and resistance thermometers.FunctionThe analog input modules convert analog signals from the process into digital signals for processing within the PLC.The modules feature: Resolution from 9 to 15 bits + sign (for different conversion times), configurable Different measuring ranges; the basic current/voltage range settings are adjusted mechanically via measurement range modules. Fine adjustments are made with the STEP 7 Hardware Configuration tool on a PG. Interrupt capability; the modules transmit diagnostic and limit value interrupts to the programmable controller’s CPU Diagnostics; the module sends detailed diagnostic information to the CPU.Technical specifications 6ES7 331-7KF02-0AB0 6ES7 331-7HF01-0AB0 6ES7 331-1KF01-0AB0 6ES7 331-7KB02-0AB0Voltages and currentsLoad voltage L+ Rated value (DC) 24 V 24 V 24 V Reverse polarity protection Yes Yes YesCurrent consumptionSeite 1 von 5CA 01 Analog Modules - Analog input SM 331 from load voltage L+ (no load), 200 mA 50 mA 80 mA max. from backplane bus 5 V DC, 50 mA 60 mA 90 mA 50 mA max. Power dissipation, typical 1W 1.5 W 0.4 W 1.3 WConnection system Requisite front connector 20-pin 20-pin 40-pin 20-pinClock synchronism Clock synchronous operation No Yes No NoAnalog inputs Number of analog inputs 8 8 8 2 Number of analog inputs for 4 8 1 resistance measurement Length of cable shielded, max 200 m; 50 m at 80 mV and 200 m 200 m; max. 50 m at 50 mV 200 m; 50 m at 80 mV and thermocouples thermocouples Permiss. input voltage for voltage 20 V; permanent; 75V for max. 1s 20 V; 20 V permanent, 75 V for max. 30 V; 12 V continuous, 30 V for max. 20 V; permanent; 75V for max. 1s input (destr. limit), max. (pulse duty ratio 1:20) 1 s (pulse duty ratio 1:20) 1s (pulse duty ratio 1:20) Perm. input volt. for the current 40 mA 40 mA 40 mA 40 mA input (destr. lim.), max.Input ranges (rated values), voltages 0 to +10 V Yes 1 to +5 V Yes Yes Yes Yes 1 to +10 V Yes No -1 V to +1 V Yes Yes Yes Yes -10 V to +10 V Yes Yes Yes Yes -2.5 V to +2.5 V Yes No Yes -250 mV to +250 mV Yes No Yes -5 V to +5 V Yes Yes Yes Yes -50 mV to +50 mV Yes -500 mV to +500 mV Yes Yes Yes -80 mV to +80 mV Yes YesInput ranges (rated values), currents 0 to 20 mA Yes Yes ...
Tìm kiếm theo từ khóa liên quan:
thủ thuật máy tính công nghệ thông tin tin học quản trị mạng computer networkGợi ý tài liệu liên quan:
-
52 trang 430 1 0
-
24 trang 355 1 0
-
Top 10 mẹo 'đơn giản nhưng hữu ích' trong nhiếp ảnh
11 trang 314 0 0 -
Làm việc với Read Only Domain Controllers
20 trang 303 0 0 -
74 trang 300 0 0
-
96 trang 293 0 0
-
Báo cáo thực tập thực tế: Nghiên cứu và xây dựng website bằng Wordpress
24 trang 289 0 0 -
Đồ án tốt nghiệp: Xây dựng ứng dụng di động android quản lý khách hàng cắt tóc
81 trang 281 0 0 -
EBay - Internet và câu chuyện thần kỳ: Phần 1
143 trang 275 0 0 -
Tài liệu dạy học môn Tin học trong chương trình đào tạo trình độ cao đẳng
348 trang 269 1 0