Thông tin tài liệu:
+ J1000 ( thay thế cho model J7 ) + V1000 ( thay thế cho model V7 ) + A1000 ( thay thế cho model F7, G5 ) + G7 + E1000 ( thay thế cho model E7 ) + L1000 ( thay thế cho model L7 )
Nội dung trích xuất từ tài liệu:
Biến tần Yaskawa BIẾN TẦN YASKAWA+ J1000 ( thay thế cho model J7 )+ V1000 ( thay thế cho model V7 )+ A1000 ( thay thế cho model F7, G5 )+ G7+ E1000 ( thay thế cho model E7 )+ L1000 ( thay thế cho model L7 ) + 1P – 220V: 0.1 ~ 2.2 Kw J1000 + 3P – 220V: 0.1 ~ 5.5 Kw + 3P – 380V: 0.2 ~ 5.5 Kw + 5 digital input Modbus comm + 1 analog input + 1 analog output + 1 relay output PG card Yaskawa Braking unit J1000 drive Start torque Overload: + 100% at 1.5 Hz + 150% with HD + 150% at 3 Hz + 120% with ND Freq range: J1000 0.01 ~ 400 Hz V/f control Speed search Yaskawa J1000 driveMax 9 speed steps ( D1) Freq jump (D3) Momentary power loss ride thru ( L2 ) + 1P – 220V: 0.1 ~ 3.7 Kw V1000 + 3P – 220V: 0.1 ~ 18.5 Kw + 3P – 380V: 0.2 ~ 18.5 Kw + 7 digital inputs + 2 analog input IM & PM motor + 1 analog output + 1 pulse in 32khz + 1 pulse out 32 khz + 1 relay output Modbus comm + 2 digit out 48Vdc Yaskawa V1000 drive Start torque PG card ~ 200% at 0.5 Hz Overload: Braking unit + 150% with HD Save parameter + 120% with ND on terminal board V1000 Freq range: Application 0.01 ~ 400 Hz preset ( A1-06 ) V/f control OLV Speed search ( B3 )Max 17 speed steps Yaskawa PID ( B5 ) ( D1 ) V1000 drive Over/under torque Freq jump (D3) detection ( L6 ) Auto turning ( T1 ) Momentary power loss ride thru ( L2 )V1000Ứng dụng:Bơm, quạt, chế tạo máy, bao bì, cầu trục … + 3P – 220V: 0.4 ~ 110 KwA1000 + 3P – 380V: 0.4 ~ 630 KwIM & PM motor Modbus comm Braking unit (==30 Kw) + 8 digital inputs + 3 analog input + 2 analog output + 1 pulse in 32khz + 1 pulse out 32 khz + 4 relay output Save parameter Overload: Start torque + 150% with HD ~ 200% at 0.3 Hz-OLVon terminal board + 120% with ND ~ 200% at 0 Hz-CLVA1000 V/f , OLV Freq range: CLV 0.01 ~ 400 Hz Application preset ( A1-06 ) Speed search (B3) PID Control (B5) Auto turning ( T1 ) Torque control (D5) Zero servo (B9)2 sets of motor parA1000Ứng dụng: + 3P – 220V: 0.4 ~ 110 Kw G7 + 3P – 380V: 0.4 ~ 300 KwIM & PM motor Fast respond 3 Level Control Braking unit (==18.5 Kw) + 12 digital inputs + 3 analog input + 2 analog output + 1 pulse in 32khz + 1 pulse out 32 khz + 4 relay, 2 trans out Save parameter Overload: Start torque + 150% in 60s ~ 150% at 0.3 Hz-OLVon terminal board + 200% in 0.5s ~ 150% at 0 Hz-CLV G7 V/f , OLV Freq range: CLV 0.01 ~ 400 Hz Application preset ( A1-06 ) Speed search (B3) PID Control (B5) Auto turning ( T1 ) Torque control (D5) Zero servo (B9)2 sets of motor parG7 Application + 3P – 380V: 3.7 ~ 355 Kw E1000 Drive for pumb & fan + 8 digital inputs + 2 analog input IM & PM motor + 2 analog output + 1 pulse in 32khzSupper energy saving + 1 pulse out 32 khz + 4 relay output Modbus comm Yaskawa E1000 drive Start torque ...