In the event of a complete Station Blackout (SBO) of a CANDU reactor, the current safety practice is to initiate depressurization early in the transient once a lack of power has been declared. This requires operator actions to manually open the main steam safety valves (MSSVs) on the secondary side initiating a crash-cool procedure.